The maximum pulling tension for 4 pair 24 awg horizontal utp cables should not exceed 110 n 25 lbf to avoid stretching the conductors during installation the requirement is 110 newtons of pulling force in metric units or 25 lbs pulling force in imperial units.
Cable pulling standards.
Pulling cables transcript each year in the u s 31 000 construction workers seek medical attention due to sprains and strains suffered on the job.
Although standards define a minimum acceptance value for the pull force according to the wire diameter and awg conductor size it is of greater importance to the manufacturer and user to know that joints can definitely sustain higher loads.
A cable pulling winch is an installer s best friend when used correctly.
Jamming minimum bending radius pulling lubricants pulling tension sidewall pressure splicing the institute of electrical and electronics engineers inc.
When pulling outdoor cables in cable pipe with narrow cross sections the use of cable lubricating grease should be considered.
These injuries happen when the human body is forced to work beyond its limits.
Complete range of products used for the installation of power cables.
3 park avenue new york ny 10016 5997 usa.
In preparing for a cable pull it is just as important to cover the small details as it is to assure that the cable does not exceed maximum sidewall pressure.
We offer large and small high tonnage diesel powered cable pulling machinery petrol and electric cable pulling winches cable pushers feeders blowers balloon line carriers blow line cable pulling rope polypropylene draw line double braided composite dyneema anti twist galvanised steel wire rope.
Cable pullers must be in good working condition their dynamometers properly calibrated and be securely mounted prior to use.
Ensure the cable pulling winch is placed at a suitable position according to the length of the cable and the condition of the site.
Minimum bending radii and maximum pulling tensions.
Cable shall be tested both before removal from cable drums and on site with a 1 kv insulation tester 5kv for mv cables.
The unit lbf stands for pounds force.
Static friction between the cable sheath and the pipe walls is minimised by the grease which makes it easier to pull the cable into the pipe.
6801 00986 ultra tugger 8 cable puller with standard force gauge.
Cable pulling from simple straight shots to pulls with multiple bends and offsets greenlee cable pulling equipment saves time increases your efficiency and safely pulls cable where you need it to be.
These devices are manufactured in various torque ratings.