It s not as flexible as romex nor it should be.
Bx wire for attic.
Set your store to see local.
I ve used this 12 2 mc cable to extend a power outlet into my walk in closet.
Wire from the basement to a first floor outlet.
Understanding these temperature ratings and matching the intent of the building code should be attempted only by a licensed electrician on a case by case basis but the electricians i ve consulted agree that it s safe under normal conditions to bury older bx cable in cellulose insulation in an attic.
For a first floor installation you will be drilling up through the floorboard and then sole plate.
Solid cu bx ac aluminum armored cable assortment.
Bx s metal sheathing runs in a helix like or twisted manner around the wires.
Since insulation is combustible you must install face plates on all attic junction boxes to prevent contact between bare wires and insulation materials.
Southwire 10 2 x 125 ft.
Bx is sheathed in a flexible metal spiral made either from aluminum or galvanized steel.
Going under alternative names such as metallic sheathed cable type ac mc greenfield or armored cable bx cable is a collection of plastic coated insulated wires typically 14 or 12 gauge bundled together and protected by a ribbon like metal sheathing.
Many in the industry may still incorrectly refer to type ac as bx cable.
From the attic or basement pull steadily on the fish tape while a helper feeds the cable into the wall opening.
Bx is also known as armor clad or flexible metal conduit cable.
But we need to know the type of wire and the type of access to the attic scuttle hole stairs to provide a complete answer.
You can attach them to the joist s side surface called the face or to the.
Add a comment 1 answer active oldest votes.
From down in the basement the bottom of the floorboards.
The abbreviation bx has stuck to all metal jacketed cables for decades.
Be gentle as you fish the cable through the hole since it is important not to tear the sheathing on the.
Edwin greenfield and gus johnson developed basic armored cable in the early 1900s.
I took it to be the cable romex was going to be exposed.
I wanted to go with mc for extra protection wired through the attic and so far it was able to withstand much of abuse from my side during the installation.
Fish the cable.
Wire from the attic to the basement near the flue blue.
Wire from the attic to the basement using a second floor hvac return green.
It may take some finessing as the tip of the fish tape blade passes through the drilled hole in the wall plate.
Wire from the attic to a second floor outlet purple.
Solid cu bx ac al armored cable armorlite cable.
Ed beal jul 19 17 at 19 08.
Junction box mounting locations there are two options for mounting boxes that are wholly contained within the attic.